TZ-Anlagen  Innotech homepage
Innotech homepage
DRYING CENTER
Technology
Technical Data
Operating Units
 
Processing
Products
 
References
Brochures
Contact
 
Deutsch
Espanol
 
INNOTECH homepageHome
Technical Data    
   

INNOTECH - Drying center

The INNOTECH Drying center is characterized by an installation completely done by heat insulation panels, a low area requirement, a flexible adjustment of the drying capacity to the yield,

an easy loading and unloading by means of trolleys, a quasi-continuous operation, "First in - First out" can be implemented.


Longitudinal- and Cross Section - Entire Unit

High flexibility in terms of thermal energy used. Alternatively gas or fossil fuel heating. Renewable energies such as solar energy or wood can also be used like waste heat of a district heating central plant.

Automatic adjustment of the heating power to the heat requirements by means of the use of high efficient modulating gas-fired water heater.


Air Flow within the Drying Center


The INNOTECH Drying center is furthermore characterized by an uniform air distribution in the drying chamber - a prerequisite for uniform drying in the entire chamber. Extensive simulation and experiments have been carried out to achieve this goal.


Model, Scale 1:10 Pressure distribution (Chamber)


Pressure Distribution within Flow Cross Section Velocity Distribution within the Boxes


Technical Data
 
Drying Chamber  
Length 10.00 m
Width 2.20 m
Total Height 3.50 m
Material Chamber 100 mm PU-Heat insulation panels
Material False Floor 45 mm PU-Heat insulation panels
Doors 2 Sliding doors, ca. 1.9 m wide
Interior Equipment 10 Stainless steel trolleys equipped with stainless steel trays
   
Technical Room  
Length 3.00 m
Width 2.20 m
Height 2.50 m
Material  Room 45 mm PU-Heat insulation panels
Door 0.90 m x 2.00 m
   
Technical Equipment  
Recirculating fans 2 High performance axial flow fans,
400V
Exhaust fan 1 High performance axial flow fan,
400 V
Standard - Heating System 2 modulating gas fired water heater
65 kW each, air-water heat exchanger
Control System Temperature control,
24 h timer